Mouth pretreatment using thiocyanate SCN safeguards versus myocardial ischaemiareperfusion damage in subjects

From Stairways
Jump to navigation Jump to search

Although it is well established that transfusion of platelets in cases of severe bleeding reduces mortality, the availability of platelets is hampered by harsh restrictions on shelf life due to elevated risks of microbial contamination and functional losses with room temperature-stored platelets (RTP) kept at 22°C. In contrast, many recent studies have shown that 4°C cold-stored platelets (CSP) are able to overcome these shortcomings leading to the recent Food and Drug Administration licensure for 14-day stored CSP when conventional platelets are unavailable. This work expands the evidence supporting superiority of CSP function by assaying the less explored platelet-mediated clot retraction of RTP and CSP in either autologous plasma (AP) or platelet additive solution (PAS) for up to 21 days. The results demonstrate that CSP have better preservation of contractile function, exhibiting retraction for up to 21 days in both AP and PAS and forming highly ordered fibrin scaffolds similar to those of fresh platelets. In contrast, RTP stored in AP showed impaired contractile function by Day 5 with no retraction after 10 days, whereas PAS-stored RTP retained contractile function for up to 21 days. Collectively, these findings support extended storage of CSP and suggest that storage in PAS can mitigate functional losses in RTP.
Civilian and military guidelines recommend early balanced transfusion to patients with life-threatening bleeding. Low titer group O whole blood was introduced as the primary blood product for resuscitation of massive hemorrhage at Haukeland University Hospital, Bergen, Norway, in December 2017. In this report, we describe the whole blood program and present results from the first years of routine use.
Patients who received whole blood from December 2017 to April 2020 were included in our quality registry for massive transfusions. Post-transfusion blood samples were collected to analyze isohemagglutinin (anti-A/-B) and hemolysis markers. Administration of other blood products, transfusion reactions, and patient survival (days 1 and 30) were recorded. User experiences were surveyed for both clinical and laboratory staff.
Two hundred and five patients (64% male and 36% female) received 836 units in 226 transfusion episodes. Patients received a mean of 3.7units (range 1-35) in each transfusion episode. The main indications for transfusion were trauma (26%), gastrointestinal (22%), cardiothoracic/vascular (18%), surgical (18%), obstetric (11%), and medical (5%) bleeding. There was no difference in survival between patients with blood type O when compared with non-group O. Haptoglobin level was lower in the transfusion episodes for non-O group patients, however no clinical hemolysis was reported. No patients had conclusive transfusion-associated adverse events. Both clinical and laboratory staff preferred whole blood to component therapy for massive transfusion.
The experience from Haukeland University Hospital indicates that whole blood is feasible, safe, and effective for in-hospital treatment of bleeding.
The experience from Haukeland University Hospital indicates that whole blood is feasible, safe, and effective for in-hospital treatment of bleeding.
Reliability of ABO-antibody measurement is important in the context of supplying low-titer ABO incompatible plasma-containing blood products. This study investigated the correlation of anti-A measurements between three different titer methodologies.
Thirty-four blood group O individuals were included. IgM and IgG anti-A was measured by three different methods (1) manual method (Bio-Rad ID-gel card), (2) automated method (Immucor NEO), (3) flow cytometry (FC) with calibration in molecules of equivalent fluorochrome (MEF). Data were log2 transformed to titer steps (TS) and log2 MEF, respectively. All three methods were benchmarked against the 14/300 WHO anti-A/anti-B standard reagent.
The correlation between the manual and automated methods was statistically significant for both IgM (Spearman's r
= 0.89, p< .0001) and IgG (r
= 0.95, p< .0001). The mean TS difference between the manual and automated methods was 0.61 for IgM (p= .0033) and 2.1 for IgG (p< .0001). The manual method yielded IgM titer results that were generally 1 titer step higher than the automated method, whereas for the IgG titrations the difference was generally a median of 2 TS higher. The FC median log2 MEF level was significantly correlated with TS of IgG and IgM for both manual and automated agglutination-based titer methods (0.69 ≤ r
≤ 0.91). With the WHO standard reagent, the manual method produced the expected results while the automated method's results were 1 TS lower for both IgM and IgG at all dilutions tested.
These results indicate that all three methods are suitable for measuring anti-A in group O whole blood.
These results indicate that all three methods are suitable for measuring anti-A in group O whole blood.
The use of blood products early in the resuscitation of bleeding trauma patients is widely accepted, but made difficult by limited supplies of D- red blood cell (RBC)-containing products. Use of D+ RBC-containing products would alleviate this issue, but could lead to alloimmunization. Risk associated with transfusing D+ RBC in emergency bleeding situations is being reconsidered. The level of concern surrounding emergency transfusion as it relates to future fetal harm was surveyed among surgeons and nurses.
Faculty and staff in the Departments of Surgery and Nursing were surveyed on the risks of receiving an emergency RBC transfusion and the subsequent potential for fetal harm. Answers were grouped as likely to accept (likely/very likely) or refuse transfusion (unlikely/very unlikely). Participants were compared by sex, and women by child-bearing age, ([15-50 years] vs. Veliparib [>50 years]).
Ninety surveys were initiated with 76 fully completed. Male (n=39) and female (n=37) respondents were comparable. Most female respondents (30/37, 81%) were of childbearing age. Overall, both males (38/39, 95%) and females (33/37, 89%; p=.19) were likely to accept a transfusion in an emergency. There was no difference in transfusion acceptance if the risk of fetal harm was presented as 1% (p=.73) or 0.1% (p=.51). Most females (34/37, 92%) were not opposed to transfusion even if there was an unspecified risk of future fetal harm.
Most of the surgeons and nurses who responded would accept a transfusion in an emergency situation even if it might lead to harming a future fetus.
Most of the surgeons and nurses who responded would accept a transfusion in an emergency situation even if it might lead to harming a future fetus.